A highly effective Damage/Leak Detection
System, SENSOR DDS, was first developed in 1991 to detect damage to
geomembrane liners which are used for municipal and hazardous waste
landfills, industrial wastes, lagoons, tanks, sedimentation basins and
similar facilities that use geomembranes.
Damage to the geomembrane is detected by electric current flow and not
the seepage of liquid. This means that the potential for liquid
leakage through the liner can be detected before serious environmental
damage occurs.
Special sensors are installed under the geomembrane liner during
construction of the containment site. These sensors are connected
by wire to a central control box located at the side of the containment
area. After completion of drainage /cover layers, an electric
source above the liner is activated and any current abnormality
resulting from a damaged liner area is detected. The data acquired
on site is interpreted by the special software which produces three
dimensional graphics identifying the actual damage positions. The
locations of these potential leakage points are advised to the site
within a few hours permitting exposure of the damaged areas and liner
repair before the site is put into service.
The system is available to perform for a period ranging from 6
months to 20 years. After completion of construction and testing
for damage and repair as required, the geomembrane liner is certified to
be "damage free". Subsequently, periodic inspections can
be arranged to suit the customer's requirements to monitor the integrity
of the liner system. In addition, a continuous monitoring system -
SENSOR DDS-CMS™ is also available. Any damage occurring is
immediately notified to the customer.
SENSOR DDS has been successfully installed since 1991 in many countries
on over 100 projects involving over 1 million m² of liner system.
Key attributes of the system are as follows:-
|

 |
Rapid and precise detection of damaged areas in geomembrane liners after
construction completion. |

 |
Systems are available for monitoring for long periods. |

 |
Simply and quickly installed. |

 |
Detects the potential for leakage before significant environmental
pollution can occur. |

 |
Used for solid waste landfills, hazardous waste containment areas,
industrial waste lagoons, tanks, mining ponds, sedimentation basins and